Chapter 7: Vital Signs

Oxygen Saturation

What is Oxygen Saturation?

Oxygen saturation refers to the percentage of hemoglobin molecules saturated with oxygen. Hemoglobin molecules can each carry four oxygen molecules; the oxygen binds or attaches to hemoglobin molecules. Oxygen saturation provides information about how much hemoglobin is carrying oxygen, compared to how much hemoglobin is not carrying oxygen.

Why is Oxygen Saturation Measured?

Healthcare providers measure oxygen saturation because it provides information about a client’s state of health. The body’s tissues and organs require oxygen for metabolism, and oxygen saturation can reveal whether there is sufficient oxygen in the blood or whether the client is in a state called hypoxemia (insufficient oxygen in the blood).

Oxygen saturation levels can influence clinical decisions about whether the client is receiving sufficient oxygen and/or requires supplemental oxygen. Oxygen saturation levels are also monitored during and after surgeries and treatments and to assess a client’s capacity for increased activity.

How is Oxygen Saturation Measured?

Oxygen saturation can be measured using a pulse oximetry device. See Figure 9 for a pulse oximeter. It is a non-invasive method that gives an instant estimate of arterial oxygen saturation levels. In critically ill clients, a more accurate, but invasive approach is drawing arterial blood or using a continuous monitoring system to measure arterial blood gases through an arterial line. An arterial line is a catheter that is inserted into an artery, usually the radial artery. It provides a way to access blood gases including arterial oxygen saturation (SaO2). Here, we focus on pulse oximetry because it is identified as a vital sign.

 

Figure 9: A pulse oximeter

A pulse oximetry device includes a sensor that measures light absorption of hemoglobin and represents arterial SpO2 (OER #1). Oxyhemoglobin and unoxygenated hemoglobin absorb light differently. The sensor measures “the relative amount of light absorbed by oxyhemoglobin and unoxygenated (reduced) hemoglobin” and compares the amount of “light emitted to light absorbed” (Jarvis, 2014, p. 164). This comparison is then converted to a ratio and is expressed as a percentage of Sp02.

Points to Consider

A pulse oximeter reading reflects arterial oxygen saturation levels, as opposed to venous oxygen saturation levels, because the device only measures light absorption of pulsatile flow: the ‘p’ in Sp02 refers to pulse or pulsatile flow. If pulsatile flow is limited or obstructed, an oxygen saturation level will not be accurate. For example, the compression of a blood pressure cuff will obliterate the pulsatile flow so blood pressure and pulse oximetry should not be taken simultaneously on the same limb.

The sensor is attached using various devices. One is a spring-loaded clip attached to a finger or toe as shown previously in Figure 9. It is used when an intermittent measurement is required. However, this clip is too large for newborns and young children, so for this population, the sensor is taped to a finger or toe. See Figure 10. This technique is also used for clients who require continuous monitoring.

Pulse oximeter with sensor taped around finger.

Figure 10: Pulse oximeter with sensor taped around finger

An earlobe clip is another useful device for clients who cannot tolerate the finger or toe clip or have a condition that could affect the results, such as vasoconstriction and poor peripheral perfusion. Another type of device is taped across the forehead and left in place for continuous monitoring. See Figure 11.

Pulse oximeter with sensor taped across forehead.

Figure 11: Pulse oximeter with device across forehead

 

 

__________________________________________________

Part of this content was adapted from OER #1 (as noted in brackets above):

© 2015 British Columbia Institute of Technology (BCIT). Clinical Procedures for Safer Patient Care by Glynda Rees Doyle and Jodie Anita McCutcheon, British Columbia Institute of Technology. Licensed under a Creative Commons Attribution 4.0 International License, except where otherwise noted. Download this book for free at http://open.bccampus.ca