Chapter 7: Vital Signs

Manual Blood Pressure Measurement

A healthcare provider uses a stethoscope and a blood pressure cuff with a sphygmomanometer to measure blood pressure manually. The stethoscope is used to listen to the blood pressure sounds, which are called Korotkoff sounds.

Stethoscope Usage and Korotkoff Sounds

The stethoscope is used on bare skin so that a client’s clothing does not affect the sounds. The stethoscope does not make sounds louder; it simply blocks out extraneous noises so you can better hear the Korotkoff sounds. These sounds are heard through a stethoscope applied over the brachial artery when the blood pressure cuff is deflating. You will not hear anything when you first place the stethoscope over the brachial artery because unobstructed blood flow is silent. The Korotkoff sounds appear after you inflate the cuff (which compresses the artery/blood flow) and then begin to deflate the cuff. The Korotkoff sounds are the result of the turbulent blood caused by the inflated cuff compressing the artery and oscillations of the arterial wall when the heart beats during cuff deflation.

Here are a few tips:

  • Use a high quality stethoscope with durable, thick tubing. Avoid stethoscopes with long tubing because this can distort sounds.
  • Ensure quiet surroundings so that you can better hear the Korotkoff sounds.
  • Make sure that the slope of the stethoscope earpieces point forward or toward your nose.
  • Use a stethoscope that has both bell and diaphragm capacity. See Figure 16 for bell and diaphragm.
Stethoscope with bell and diaphragm capacity

Figure 16: Stethoscope with bell and diaphragm (Illustration credit:  Hilary Tang).

  • Cleanse the stethoscope prior to use including the ear pieces and the bell and diaphragm.
  • The bell of the stethoscope is suggested because it is used for low-pitched sounds like blood pressure. However, some healthcare providers use the diaphragm for several reasons: that is how they learned to take blood pressure; they believe this helps them hear the Korotkoff sounds better; and the diaphragm covers a larger surface area than the bell.
  • Hold the bell lightly against the skin with a complete seal or hold the diaphragm firmly against the skin with a complete seal.
  • You must ensure that the bell or diaphragm is open before using. See Film Clip 5 on how to open and close the bell and diaphragm.

Film Clip 5: Opening and closing the bell and diaphragm.

Determining Maximum Inflation Pressure

Healthcare providers determine the maximum inflation pressure before they take blood pressure. The maximum inflation pressure is the number on the sphygmomanometer that the cuff is inflated to when measuring blood pressure. If you do not determine the maximum pressure inflation, an auscultatory gap could go unrecognized, and as a result the blood pressure could be underestimated (lower than the actual value).

An auscultatory gap is a silent interval when the Korotkoff sounds go absent and then reappear while you are deflating the cuff during blood pressure measurement. This gap is an abnormal finding and can occur due to arterial stiffness and arteriosclerotic disease. It is typically observed in people with a history of hypertension who have been treated with prolonged antihypertensive medication.

To determine the maximum inflation pressure, start by palpating the brachial or radial pulse while inflating the cuff. Inflate the cuff 30 mm Hg quickly past the point when you obliterate the pulse (ie., you no longer feel the pulse). If you still cannot feel the pulse, use that value to start auscultating – that value is the maximum inflation pressure number.

When taking blood pressure, if an auscultatory gap is observed, document the first systolic sound and diastolic sound only. Report the presence of an auscultatory gap in narrative notes.

Points to Consider

Generally, auscultatory gaps do not interfere with automatic blood pressure measurements (Fech, et al., 2012). However, if a client’s blood pressure reading is suspiciously high or low, the healthcare provider takes blood pressure manually.

Blood Pressure Measurement Techniques

For novices, it is a good idea to start with the two-step technique and then move onto the one-step technique as you develop your skills.

Two-step technique 

First step: Determining maximum pressure inflation

Palpate the radial or brachial artery, inflate the blood pressure cuff until the pulse is obliterated, and then continue to inflate 30 mm Hg more (OER #1). Note this number – it is considered the maximum pressure inflation. Next, deflate the cuff quickly by fully opening the valve.

Second step: Measure blood pressure

Now, you can start to measure blood pressure. Place the bell of the cleansed stethoscope over the brachial artery (OER #1) using a light touch and complete seal. Inflate the cuff to the maximum pressure inflation number (OER #1). Open the valve slightly. Deflate the cuff slowly and evenly (OER #1) at about 2 mm Hg per second. See Film Clip 6 which focuses on the speed of the needle when deflating the blood pressure cuff.

Note the points at which you hear the first appearance of Korotkoff sounds (systolic blood pressure) (OER #1) and the point at which the Korotkoff sounds go silent (diastolic blood pressure) (Hypertension Canada, 2020). These sounds are called Korotkoff sounds and vary in quality from tapping, swooshing, muffled sounds, and silence. The pressure at which the first Korotkoff sound is noted signifies the systolic pressure, while the pressure at which the Korotkoff sounds are no longer heard marks the diastolic pressure. See Audio Clip 2 to listen to Korotkoff sounds and noting systolic and diastolic blood pressure.

Film Clip 6: Deflation rate of sphygmomanometer.

 

Next, you have the opportunity to observe the two-step blood pressure approach and then try it out yourself – see Film Clip 7. This approach is best used when you are first learning how to take blood pressure.

 

Film Clip 7: Two-step blood pressure approach (NOTE: The diastolic is the point at which the Korotkoff sounds go silent [Hypertension Canada, 2020]. Please note, this video was taken prior to the release of these new guidelines).

 

Audio Clip 2: Korotkoff sounds with blood pressure.

One-step technique: Determining maximum pressure inflation and taking blood pressure

Palpate the radial or brachial artery, inflate the blood pressure cuff until the pulse is obliterated (OER #1), and then continue to quickly inflate 30 mm Hg more (Hypertension Canada, 2020). Place the bell of the cleansed stethoscope over the brachial artery (OER #1) using a light touch with a complete seal. Open the valve slightly. Deflate the cuff slowly and evenly (OER #1) at about 2 mm Hg per second. Note the points at which you hear the first Korotkoff sound (systolic blood pressure) (OER #1) and the point in which the Korotkoff sounds go silent (diastolic blood pressure) (Hypertension Canada, 2020). These sounds are called Korotkoff sounds and vary in quality from tapping, swooshing, muffled sounds, and silence. The first Korotkoff sound is the systolic pressure, and the diastolic pressure is when the Korokoff sounds go silent.

Watch this teaching video of a film clip that shows the one-step blood pressure approach – see Film Clip 8. After you become proficient in the two-step approach, you can move on to the one-step blood pressure approach.

Film Clip 8: One-step blood pressure approach.

 

Points to Consider 

Korotkoff sounds are the sounds of blood flow through the artery as you are listening to blood pressure. Korotkoff sounds are not the same thing as the heart beat or the pulse. They disappear as the cuff is inflated and reappear as the cuff is deflated. They also cannot be heard when the cuff is fully deflated because unobstructed and healthy blood flow is silent. When deflating the cuff, the first Korotkoff sound is systolic and the point in which the Korotkoff sounds are no longer heard is diastolic (Hypertension Canada, 2020). In rare cases, the Korotkoff sounds continue to 0 mm Hg. In this case, the diastolic pressure should be measured when the Korotkoff sounds become muffled (Hypertension Canada, 2020).

Test Your Knowledge

 

___________________________________________________
Part of this content was adapted from OER #1 (as noted in brackets above):
© 2015 British Columbia Institute of Technology (BCIT). Clinical Procedures for Safer Patient Care by Glynda Rees Doyle and Jodie Anita McCutcheon, British Columbia Institute of Technology. Licensed under a Creative Commons Attribution 4.0 International License, except where otherwise noted. Download this book for free at http://open.bccampus.ca